SPECIFICATIONS

OUTPUT


Model

SV-3000-24

SV-3000-48

SV-3000-110

DC Voltage

24V

48V

110V

Rated Current

120A

60.0A

27.3A

Current Range

0-120A

0-60.0A

0-27.3A

Ripple & Noise

0.50%

0.50%

0.50%

Voltage Adj. Range

0-24V

0-48V

0-110V

Setup&Rise Time

100ms,50ms at full load

Hold Up Time

20ms at full load

INPUT


Voltage Range

AC220V±20%     47~63HZ

AC Current

3.2A/115V     1.6A/230V

Efficiency

86%

87%

89%

Inrush Current

40A/230V

Leakage Current

<0.5MA/230VAC

PROTECTION


Over Load

110~150%

Protection type: Shut down o/p voltage, re-power on to recover

Over Voltage

110~150%

Protection type: Shut down o/p voltage, re-power on to recover

SAFETY


Withstand Voltage

I/P-O/P:1.5KVAC/1min           I/P-F/G:1.5KVAC/1min

Isolation Resistance

O/P-F/G:0.5KVAC /1min

Weight

9.5kg/piece

Dimension

400*220*150mm

NOTE


1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.

2.Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1μ & 47μ parallel capacitor.

3.Tolerance: includes set up tolerance, line regulation and load regulation

4.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.

Features:

·High efficiency, high reliability
100% full load burn-in test
Protection: Short circuit/ Over load / Over voltage

Dimensions:300*150*130(mm)


SPECIFICATIONS
OUTPUT
ModelSV-2000-12SV-2000-15SV-2000-24SV-2000-30SV-2000-48SV-2000-110
DC Voltage12V15V24V30V48V110V
Rated Current166A133.0A83.3A66.0A41.6A18A
Current Range0-166A0-133.0A0-83.3A0-66.0A0-41.6A0-18.0A
Ripple & Noise160mV180mV190mV320mV400mV900mV
Voltage Adj. Range0.50%0.50%0.50%0.50%0.50%0.50%
Setup&Rise Time100ms,50msat full load
Hold Up Time20ms at full load


INPUT
Voltage RangeAC220V±20%   47~63HZ
AC Current3.2A/115V1.6A/230V
Efficiency86%86%87%87%89%89%
Inrush Current40A/230V
Leakage Current<0.5MA/230VAC


PROTECTION
Over Load110~150%
Protection type: Shut down o/p voltage, re-power on to recover
Over Voltage110~150%
Protection type: Shut down o/p voltage, re-power on to recover
SAFETY
Withstand VoltageI/P-O/P:1.5KVAC/1min I/P-F/G:1.5KVAC/1min
Isolation ResistanceO/P-F/G:0.5KVAC /1min
Gross weight6.0kg
Dimension300*150*130mm
NOTE
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2.Ripple & noise are measured at 20MHz of bandwidth by using a 12”twisted pair-wire terminated with a 0.1μ &47μparallel capacitor.
3.Tolerance: includes set up tolerance, line regulation and load regulation
4.The power supply is considered a component which will be installed into a final equipment. The final equipment mustbe re-confirmed that it still meets EMC directives.


Previous: 
Next: 
Professional manufacturer, quality is our culture!
READ MORE>>

Subscribe

Products

Quick Links

Contact Us

Tel: 0086-577-27852809
Fax: 0086-577-61738060
Mob: 0086-13757875820
Whatsapp:0086-13757875820
E-mail: wstele@wstele.net
Skype:wstele
QQ: 2853768221
​Copyright © 2016 YUEQING WINSTON ELECTRIC CO.,LTD  All Rights Reserved. Site Map